Sievers 800 and 2244 AP
After its introduction in 1993, the Sievers Model 800 TOC Analyzer Series (including the 2244 AP) became one of the best-selling instruments for TOC analysis, with more than 3500 installations worldwide. In June 2004, GE Analytical Instruments introduced the next generation of this popular product — the 900 Series TOC Analyzers. GE Analytical Instruments discontinued production of the Model 800 in December, 2004.
Next Generation Analyzers
The 900 Series, consisting of four main TOC analyzer models and the 900 Autosampler, is based on the Model 800's proven technology. The next-generation Sievers 900 Series offers many additional features for enhanced ease of use, analytical performance, and productivity, and includes:
- 900 Laboratory
- 900 On-Line
- 900 Portable
- 900 Autosampler
- 5310 C Laboratory
- 5310 C On-Line
800 / 2244 AP Standards
Part Number |
Description |
Annual Kits |
|
|---|---|
| STD KIT8D | Annual Pharmaceutical Standards Kit - Daily Systems Suitability Testing |
|
To order this kit, use part numbers and quantities below: 260 x CSTD 31004 (System Suitability Set) - 10 sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss) |
|
| STD KIT8M | Annual Pharmaceutical Standards Kit - Monthly Systems Suitability Testing |
|
To order this kit, use part numbers and quantities below: 2 x CSTD 31004 (System Suitability Set) - Shipped one per month. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss) |
|
| STD KIT8Q | Annual Pharmaceutical Standards Kit -Quarterly Systems Suitability Testing |
|
To order this kit, use part numbers and quantities below: 4 x STD 31004 (System Suitability Set) - Shipped one per quarter. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss) |
|
| STD KIT8W | Annual Pharmaceutical Standards Kit -Weekly Systems Suitability Testing |
|
52 x CSTD 31004 (System Suitability Set) - Two sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss) |
|
System Suitability |
|
| CSTD 31004-01 | System Suitability Set - 800/900 Series |
| Includes 1 Rw - Reagent Water Control, 1 Rs - Standard Solution and 1 Rss - System Suitability Solution. | |
| CSTD 31007-01 | System Suitability Set - 800 Autosampler Mode |
| Includes 2 Rw - Reagent Water Control, 2 Rs - Standard Solution and 2 Rss - System System suitability Solution. | |
Calibration Standards |
|
| CSTD 31001-01 | Calibration Standards Set, Grab Mode - 800 Series |
| Includes 2 calibration blanks, 2 TOC calibration standards (25 mg C/L as KHP), and 2 IC calibration standards (25 mg C/L as Na2CO3. | |
| CSTD 31002-01 | Calibration Standards Set, Autosampler - 800 Series |
| Includes 4 calibration blanks, 4 TOC calibration standards (25 mg C/L as KHP), and 4 IC calibration standards (25 mg C/L as Na2CO3). | |
Verification Standards |
|
| CSTD 31013-01 | Accuracy and Precision Set - 800/900 Series |
| Includes 1 Rw - reagent water control and 1 Rs - Standard Solution | |
Validation Standards |
|
| CSTD 31012-01 | Linearity Standards Set - 800/900 Series |
| Includes 1 each 250 µg C/L, 500 µg C/L, 750 µg C/L as USP Sucrose and 1 reagent water blank | |
| CSTD 38001-02 | Validation Standards Set, Grab - 800 Series |
| Includes three Calibration Blanks, three TOC Calibration Standards, three IC Calibration Standards, two System Suitability Sets, one Linearity Set and one Accuracy/Precision Set. | |
| CSTD 38101-02 | Validation Standards Set, Autosampler - 800 Series |
| Includes six Calibration Blanks, six TOC Calibration Standards, six IC Calibration Standards, four System Suitability Sets (CSTD 31004), one Linearity Set and one Accuracy/Precision Set. | |