The Sievers 900 On-Line Turbo TOC Analyzer is ideal for semiconductor reclaim analysis.

900 On-Line TOC Turbo Specifications

The Sievers 900 On-Line Turbo TOC Analyzer is:

Operating Specifications1
Range 0.20 ppb to 10 ppm
Precision 2% RSD
Accuracy ± 3%
Display Readout 3 significant digits
Sample Type On-line continuous
Calibration Typically stable for 12 months
Analysis Time 4 seconds
t52 Time to detect 5% of TOC step change
t902 Time to detect 90% of TOC step change
Sample Temperature2 1–95 °C (34–203 °F)
Ambient Temperature 10–40 °C (50–104 °F)
Sample Pressure3 Up to 250 psi
Sample Flow Rate 30–300 mL/min (for on-line mode)
Instrument Sample
Flow Rate
1.1. ml/min; 0.5 mL/min when TOC >5 ppm
Analyzer Specifications
Outputs 4-20mA output (1); alarm outputs (2); binary output (1); Serial RS-232 output (1); USB port (1); parallel printer port (1)
Display Quarter-VGA, color touch-screen display
Power Universal Power Supply: 100–240 ± 10% VAC, 50 W, 50/60 Hz
Dimensions H: 62.4 cm (24.6 in); W: 45.2 cm (17.8 in); D: 26.4 cm (10.4 in)
Weight 16.9 kg (37.2 lb)
Safety Certifications ETL, CE
Industrial Ratings IP-45 Enclosure
Consumables
UV Lamp 6 months
Acid Reagent As needed, typically 6 months (285 mL)
Oxidizer Reagent As needed, typically 3-month stability; available in 150- or 300-mL cartridge

1 Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.
2 When TOC is less than 5 ppm.
3 If the sample temperature and pressure are above 60 °C and 100 psi, the 900 Analyzer model with the stainless steel iOS is required.