Standards for both 5310 C On-Line and 5310 C Laboratory TOC Analyzers

5310 C On-Line Standards

The following Certified Reference Materials for the Sievers 5310 C TOC Analyzers are packaged in 40-mL glass vials and are available in annual kits, sets, or as individual vials.

•  Check Standards
•  Calibration
•  Verification

 Part Number
 Description

Check Standards

CSTD 90031 Municipal TOC Verify Set (V1.40+)
 

Municipal TOC standards set for Sievers 5310C equipped with firmware versions 1.40 or greater. Includes one 1 mg C/L, one 5 mg C/L and one 10 mg C/L as KHP standard. Packaged in 40 mL vials.

Calibration Standards

CSTD 90001-01 900/5310 C Single-Point Calibration Standards Set - 1 mg/L
 

Includes: one Calibration Blank, one 1 mg C/L TOC Calibration Standard (as KHP) and one 1 mg C/L IC Standard (as Na2CO3).

CSTD 90002-01 900/5310 C Single-Point Calibration Standards Set - 5 mg/L
 

Includes: one Calibration Blank, one 5 mg C/L TOC Calibration Standard (as KHP) and one 5 mg C/L IC Standard (as Na2CO3).

CSTD 90003-01 900/5310 C Single-Point Calibration Standards Set - 10 mg/L
 

Includes: one Calibration Blank, one 10 mg C/L TOC Calibration Standard (as KHP) and one 10 mg C/L IC Standard (as Na2CO3).

CSTD 90004-01 900/5310 C Single-Point Calibration Standards Set - 25 mg/L
 

Includes: one Calibration Blank, one 25 mg C/L TOC Calibration Standard (as KHP) and one 25 mg C/L IC Standard (as Na2CO3).

CSTD 90005-01 900/5310 C Single-Point Calibration Standards Set - 50 mg/L
 

Includes: one Calibration Blank, one 50 mg C/L TOC Calibration Standard (as KHP) and one 50 mg C/L IC Standard (as Na2CO3).

CSTD 90016-01 900 Single-Point Calibration and Verification Set - 1 mg/L
 

Includes: 1 TOC Calibration Set and 1 Verification Standards Set

CSTD 90017-01 900 Single-Point Calibration and Verification Set - 5 mg/L
 

Includes: 1 TOC Calibration Set and 1 Verification Standards Set

CSTD 90018-01 900 Single-Point Calibration and Verification Set - 10 mg/L
 

Includes: 1 TOC Calibration Set and 1 Verification Standards Set

CSTD 90019-01 900 Single-Point Calibration and Verification Set - 25 mg/L
 

Includes: 1 TOC Calibration Set and 1 Verification Standards Set

CSTD 90020-01 900 Single-Point Calibration and Verification Set - 50 mg/L
 

Includes: 1 TOC Calibration Set and 1 Verification Standards Set

CSTD 90028 900 Autoreagents Calibration and Verification Set
 

Includes one TOC Calibration Blank, one 25 mg C/L TOC Calibration Standard (as KHP), one 25 mg C/L IC Calibration Standard (as Na2CO3), and one 50 mg C/L TOC Challenge Standard (as Nicotinamide). Verification includes one TOC Verification Blank, one 25 mg C/L TOC Verification Standard (as NIST sucrose), one 50 mg C/L TOC Verification Standard (as NIST sucrose), and one 50 mg C/L IC Verification Standard (as Na2CO3). Applicable to firmware version 1.20 and later.

CSTD 96000-01 5310 C, Multi-Point Calibration Set (V1.40 or later)
 

Multi-point calibration standards set for Sievers 5310C equipped with firmware versions 1.40 or later. Includes: one Calibration Blank, five TOC Calibration Standards (250µg C/L,1,5,25,50 mg C/L TOC as KHP) and five IC Calibration Standards (1,5,10,25,50 mg C/L IC as Na2CO3).

CSTD 90036 900 Autoreagents Calibration Set
 

Includes one TOC Calibration Blank, one 25 mg C/L TOC Calibration Standard (as KHP), one 25 mg C/L IC Calibration Standard (as Na2CO3), and one 50 mg C/L TOC Challenge Standard (as Nicotinamide). Applicable to firmware version 1.20 and later.

Verification Standards

CSTD 90008-01 900/5310 C Single-Point Verification Set, 1 mg/L
 

Includes: one Verification Blank, one 1 mg C/L TOC Verification Standard (as NIST Sucrose) and one 1 mg C/L IC Standard (as Na2CO3).

CSTD 90009-01 900/5310 C Single-Point Verification Set - 2 mg/L
 

Includes: one Verification Blank, one 2 mg C/L TOC Verification Standard (as NIST Sucrose) and one 2 mg C/L IC Standard (as Na2CO3).

CSTD 90010-01 900/5310 C Single-Point Verification Set - 5 mg/L
 

Includes: one Verification Blank, one 5 mg C/L TOC Verification Standard (as NIST Sucrose) and one 5 mg C/L IC Standard (as Na2CO3).

CSTD 90011-01 900/5310 C Single-Point Verification Set - 10 mg/L
 

Includes: one Verification Blank, one 10 mg C/L TOC Verification Standard (as NIST Sucrose) and one 10 mg C/L IC Standard (as Na2CO3).

CSTD 90012-01 900/5310 C Single-Point Verification Set - 25 mg/L
 

Includes: one Verification Blank, one 25 mg C/L TOC Verification Standard (as NIST Sucrose) and one 25 mg C/L IC Standard (as Na2CO3).

CSTD 90013-01 900/5310 C Single-Point Verification Set - 50 mg/L
 

Includes: one Verification Blank, one 50 mg C/L TOC Verification Standard (as NIST Sucrose) and one 50 mg C/L IC Standard (as Na2CO3).

CSTD 90034 900/5310 C Autoreagents Verification Set
 

Includes one TOC Verification Blank, one 25 mg C/L TOC Verification Standard (as NIST sucrose), one 50 mg C/L TOC Verification Standard (as NIST sucrose), and one 50 mg C/L IC Verification Standard (as Na2CO3). Applicable to firmware version 1.20 and later.

To place an order, please contact Customer Service or order online. To learn more about our Web store, visit http://www.geinstruments.com/ionics/index.cfm?category_code=Web%20Store