To order this kit, use the following part numbers and quantities:
12 x CSTD 74503 (System Suitability Set) - Shipped one per month. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super iOS System.
|
| |
To order this kit, use the following part numbers and quantities:
4 x CSTD 74503 (System Suitability Set) - Shipped one per quarter. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super iOS System.
|
| STD KIT5WS |
Annual Pharmaceutical Standards Kit for Weeky Testing |
| |
To order this kit, use the following part numbers and quantities:
52 x CSTD 74503 (System Suitability Set) - Two sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super iOS System.
|
500 RL with Standard iOS
|
| STD KIT5M |
Annual Pharmaceutical Standards Kit for Monthly Testing |
| |
To order this kit, use the following part numbers and quantities:
12 x CSTD 74403 (System Suitability Set) - Shipped one per month. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss).
|
| STD KIT5Q |
Annual Pharmaceutical Standards Kit for Quarterly Testing |
| |
To order this kit, use the following part numbers and quantities:
4 x CSTD 74403 (System Suitability Set) - Shipped one per quarter. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss).
|
| STD KIT5W |
Annual Pharmaceutical Standards Kit for Weekly Testing |
| |
To order this kit, use the following part numbers and quantities:
52 x CSTD 74403 (System Suitability Set) - Two sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss).
|
System Suitability and Compendial Standards
|
500 RL with Super iOS
|
| CSTD 74503 |
500 Super iOS System Suitability |
| |
Includes one Reagent Water Blank - Rw, one Standard Solution - Rs (500 µg C/L as USP Sucrose), one Standard Solution - Rss (500 µg C/L as USP 1.4-Benzoquinone), and one Rinse Water Standard. These standards are package in a vial set cartridge for use with the Sievers Super iOS System.
|
500 RL with Standard iOS
|
| CSTD 74403 |
500 System Suitability Set |
| |
Includes one Reagent Water Blank - Rw, one Standard Solution - Rs (500 µg C/L as USP Sucrose), one Standard Solution - Rss (500 µg C/L as USP 1,4-Benzoquinone), and one Rinse Water Standard.
|
Japanese Pharmacopoeia Testing
|
| CSTD 74529-01 |
500 RL with Super iOS Japanese (JP) Protocol Set (TOC) |
| |
This standard set meets the new Japanese Pharmacopoeia TOC requirements and includes: (2) 30-mL plastic vial standards, (1) reagent water blank, (1) 500-µg C/L as SDBS standard, and (1) empty glass vial for alignment.
|
Calibration Standards
|
500 RL with Super iOS
|
| CSTD 74501 |
500 Super iOS Single Point Cal ibration Set |
| |
Includes two Calibration Blanks, one 1.5 mg C/L TOC Calibration Standard (as KHP) and one 25 µS/cm Conductivity Standard (as HCI). These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74505 |
500 Super iOS Single Point Calibration - TOC Only |
| |
Includes two Calibration Blanks and one 1.5 mg C/L TOC Calibration Standard (as KHP) packaged in a vial set cartridge for use with the Sievers Super iOS System. Not compatible with 500 RL instruments equipped with the conductivity option.
|
| CSTD 74512 |
500 Super iOS Single Point Calibration/Verification |
| |
Includes: one Single Point Calibration Set and one Accuracy/Precision & Verification Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74514 |
500 Super iOS Multi-Point Calibration Set |
| |
Includes three Calibration Blanks, three TOC Calibration Standards (500 µg C/L, 1.0 mg C/L, 1.5 mg C/L as KHP) and one 25 µS/cm Conductivity Standard (as HCI). These standards are package in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74516 |
500 Super iOS Multi-Point Calibration/Verification |
| |
Includes: one Multi-Point Calibration Set and one Accuracy/Precision/Verification Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74522 |
500 Super iOS Single-Point Calibration/Verification - TOC Only |
| |
Includes one Single Point Calibration Set and one Accuracy/Precision & Verification Set packaged in vial set cartridges for use with the Sievers Super iOS System. Not compatible with 500 RL instruments equipped with the conductivity option.
|
| CSTD 74524 |
500 Super iOS Multi-Point Calibration Set - TOC Only |
| |
To order this kit, use the following part numbers and quantities:
52 x CSTD 74503 (System Suitability Set) - Two sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss). These standards are packaged in a vial cartridge for use with the Sievers Super iOS System.
|
| CSTD 74526 |
500 Super iOS Multi-Point Calibration/Verification Set - TOC Only |
| |
Includes: one Multi-Point TOC Calibration Set and one TOC Accuracy/Precision/Verification Set packaged in vial set cartridges for use with the Sievers Super iOS System. Not compatible with 500 RL instruments equipped with the conductivity option.
|
500 RL with Standard iOS
|
| CSTD 74401 |
500 Single-Point Calibration Set |
| |
Includes two Calibration Blanks, one 1.5 mg C/L TOC Calibration Standard (as KHP) and one 25 µS/cm Conductivity Standard (as HCl).
|
| CSTD 74405 |
500 Single-Point Calibration Set - TOC Only |
| |
Includes two Calibration Blanks and one 1.5 mg C/L TOC Calibration Standard (as KHP). Conductivity standards are not included in this set.
|
| CSTD 74612 |
500 Single-Point Calibration/Verification Set |
| |
Includes: one Single Point Calibration Set and one Accuracy/Precision & Verification Set.
|
| CSTD 74614 |
500 Multi-Point Calibration Set |
| |
Includes three Calibration Blanks, three TOC Calibration Standards ( 500 µg C/L, 1.0 mg C/L, 1.5 mg C/L as KHP) and one 25 µS/cm Conductivity Standard (as HCl).
|
| CSTD 74616 |
500 Multi-Point Calibration/Verification Set |
| |
Includes: one Multi-Point Calibration Set and one Accuracy/Precision & Verification Set.
|
| CSTD 74622 |
500 Single-Point Calibration/Verification Set - TOC Only |
| |
Includes: one Single Point Calibration Set and one Accuracy/Precision & Verification Set. Conductivity standards are not included in this set.
|
| CSTD 74624 |
500 Multi-Point Calibration Set - TOC Only |
| |
Includes three Calibration Blanks, and three TOC Calibration Standards (500 µg C/L, 1.0 mg C/L, 1.5 mg C/L as KHP). Conductivity standards are not included in this set.
|
| CSTD 74626 |
500 Multi-Point Calibration/Verification Set - TOC Only |
| |
Includes: one Multi-Point Calibration Set and one Accuracy/Precision & Verification Set. Conductivity standards are not included in this set.
|
Verification Standards
|
500 RL with Super iOS
|
| CSTD 74502 |
500 Super iOS Accuracy/Precision/Verification Set |
| |
Includes one Verifcation Blank, one 500 µg C/L TOC Verification Standard (as NIST Sucrose) and one 25µS/cm Conductivity Standard (as HCI). These standards are package in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74507 |
500 Super iOS Accuracy/Precision/Verification - TOC Only |
| |
Includes one Verification Blank and one 500 µg C/L TOC Verification Standard (as NIST Sucrose packaged in a vial set cartridge for use with the Sievers Super iOS System. Not compatible with 500 RL instruments equipped with the conductivity option.
|
500 RL with StandardiOS
|
| CSTD 74402 |
500 Accuracy/Precision/Verification Set |
| |
Includes one Verification Blank, one 500 µg C/L TOC Verification Standard (as NIST Sucrose) and one 25 µS/cm Conductivity Standard (as HCl).
|
| CSTD 74407 |
500 Accuracy/Precision/Verification - TOC Only |
| |
Includes one Verification Blank and one 500 µg C/L TOC Verification Standard (as NIST Sucrose). Conductivity standards are not included in this set.
|
Validation Standards
|
500 RL with Super iOS
|
| CSTD 74506 |
500 Super iOS Linearity Set |
| |
Includes, one each 250 µg C/L, 500 µg C/L, 750 µg C/ as KHP and one Linearity Blank. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74513 |
500 Super iOS Single-Point Validation |
| |
Includes: one Single Point Calibration Set, two Accuracy/Precision & Verification Sets, one System Suitability Set, and one Linearity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
| CSTD 74515 |
500 Super iOS Multi-Point Validation |
| |
Includes: one Multi-Point Calibration Set, two Accuracy/Precision & Verification Sets, one System Suitability Set, and one Linearity Set. These standards are packaged in a vial set cartridge for use with the Sievers Super iOS System.
|
500 RL with Standard iOS
|
| CSTD 74406 |
500 Linearity Set |
| |
Includes, one each 250 ug C/L, 500 ug C/L, 750 ug C/L as KHP and one Linearity Blank.
|
| CSTD 74613 |
500 Single-Point Validation |
| |
Includes: one Single Point Calibration Set, two Accuracy/Precision & Verification Sets, one System Suitability Set, and one Linearity Set.
|
| CSTD 74615 |
500 Multi-Point Validation |
| |
Includes: one Multi-Point Calibration Set, two Accuracy/Precision & Verification Sets, one System Suitability Set, and one Linearity Set.
52 x CSTD 74403 (System Suitability Set) - Two sets shipped every two weeks. System Suitability Set includes one Reagent Water Control (Rw), one Standard Solution (Rs), and one System Suitability Solution (Rss).
|