The ID-233 comes in three models which measure water level fluctuations up to 500 mm (19.7 in), 2000 mm (6.6 ft), or 2500 mm (8.2 ft).
ID-223 Specifications
The ID-223 floating sensor is capable of monitoring hydrocarbons and other organic solvents on flowing water and in wet and dry sumps. Specifications include:
| ID-223 Operating Range | |
|---|---|
| Resolution | 0.3 mm (0.01 in) of hydrocarbon on water or brine |
| Measuring Range | 0.3–25 mm (0.01–1.0 in) of hydrocarbon on water or brine |
| Water Level Variation | Various ranges are available: Minimum: 40–70 mm (1.6–2.8 in); Maximum: 2,500 mm (8.2 ft) |
| Water Lateral Velocity | ~30 cm/sec (~11.8 in/sec) without a stilling well (may be doubled with a stiller |
| Temperature | 0–70° C (32–158° F) |
| ID-223 Physical Specifications | |
| Model ID-223/500 | |
| Sensor Floating Range |
40-500 mm (1.6-19.7 in) |
| Guiding Cage Diameter | 180 mm (7.1 in) |
| Sensor Diameter | 160 mm (6.3 in) |
| Model ID-223/2000 | |
| Sensor Floating Range |
70-2000 mm (2.8-78.7 in) |
| Guiding Cage Diameter | 560 mm (22.1 in) |
| Sensor Diameter | 160 mm (6.3 in) |
| Model ID-223/2500 | |
| Sensor Floating Range |
70-2500 mm (2.8-98.4 in) |
| Guiding Cage Diameter | 280 mm (11.0 in) |
| Sensor Diameter | 160 mm (6.3 in) |
| Specifications Common to all 3 Models Above | |
| Sensor Materials |
Hydrocarbon resistant polymers, 316 stainless steel |
| Cable | 10 m (~33 ft) supplied with sensor, 3 x 18 AWG, blue PVC jacket |
| PS-220 Controller Specifications | |
|---|---|
| PS-220 Description | The PS-220 Controller is an analog signal processor and power supply in a NEMA enclosure that comes standard with the ID-223. |
| Temperature | Ambient temperature range: -40–85° C (-40–185° F) |
| Cable distance to PS-220 | Up to 1,200 m (3,937 ft) subject to hazardous area restrictions |
| PS-220/RL/LI | Two alarm relay contacts and one fail contact: SPDT rated 4A (3A for fail contact) at 250 VAC or 30 VDC, normally open and normally closed, and four indicating lights: Air/Oil/Water/Fail. Includes built-in diagnostics feature. |
| Wiring Connections | 14 AWG maximum for sensor and 4-20 mA output wires; 12 AWG maximum for power and relays wires |
| PS-220 Controller Options | |
| Enclosure Options |
NEMA 4X (IP-65): 300 x 190 x 120 mm (12.0 x 7.5 x 4.7 in) (standard enclosure); NEMA 7: 278 x 259 x 166 mm (11.0 x 10.2 x 6.5 in); EEx d: 302 x 233 x 154 mm (12.0 x 9.2 x 6.1 in) |
| Input Power Options | 220/110 VAC, 9–36 VDC (@ 5 Watts), may also be solar powered |
| PS-220 420 | 4–20 mA signal proportional to hydrocarbon thickness up to 25 mm (1.0 in)—current source |
| PS-220 420/BG | Bar graph display (20 bars) of hydrocarbon thickness and 4-20 mA output |
| AUD | Audio alarm option (available in weather- or explosion-proof enclosure) |
| Other Controllers | |
| WSP-220 | Wireless communication (consult factory for more details) |
| DSP-220 | Digital Signal Processor for Multiple ID-220 Series (8 standard, up to 40 optional) Sensor Control with various output options, including: relays, lights, 4-20 mA and RS-232 or RS-422 communications (consult factory for more details) |
| Sensor and Controller Certifications | |
|---|---|
| ID-223 Sensor | Intrinsically Safe — EEx ia IIC T4 |
| PS-220 Enclosure | For hazardous areas: North America — NEMA 7, Class I, Div 1, Groups B, C & D; NEMA 4 Europe — ATEX EEx d IIC T6 IP66 |
| Combined System Performance | Approved for operation in hazardous location EPA — Conforms to EPA/530/UST-90-009 for groundwater monitoring systems TÜV — Type approval in accordance with WHG (Water Resources Law) § 19 h |
| Manufacturing | ISO 9001 Certified |
| Safety | CE Certified |